MODEL  |    STANDARD  |    STANDARD   explosion proof  |    PORTABLE  |   
Nature of equipment  |    Fixed  |    Fixed  |    Portable  |   
Detection in pipe    under load  |    Yes  |    Yes  |    Yes  |   
Flow measurement    on open channel  |    No  |    No  |    No  |   
External o of pipe  |    100mm to 1500mm / 4’’ to 60’’  |    100mm to 1500mm / 4’’ to 60’’  |    100mm to 1500mm / 4’’ to 60’’  |   
Inputs/Outputs  |    › 2 analogue outputs    › 2 static relay outputs  |    › 2 analogue outputs    › 2 static relay outputs  |    › 2 analogue outputs    › 2 static relay outputs  |   
Use  |    Detection of the passing    of a sphere or pig and change    of product in the pipe  |    Detection in an explosive    environment of the passing    of a sphere or pig and change    of product in the pipe  |    Detection of the passing    of a sphere or pig and change    of product in the pipe  |   
In option,    2U 19’ ’ rack  |    Available  |    ||
Single or dual pipe  |    Single pipe  |    Single pipe  |    Single pipe  |   
Single or dual chord  |    Single chord  |    Single chord  |    Single chord  |   
Display  |    › Alphanumeric (2 lines x 16 characters)    › Backlit LCD screen with time delay   feature  |    › Alphanumeric (2 lines x 16 characters)    › Backlit LCD screen with time delay   feature  |    › Alphanumeric (2 lines x 16 characters)    › Backlit LCD screen with time delay   feature  |   
Set-up  |    › Q uick and simple using 4-key touch pad - or - via   dedicated software supplied    › P ossible to build in an access code  |    › Q uick and simple using 4-key touch pad - or - via   dedicated software supplied    › P ossible to build in an access code  |    › Q uick and simple using 4-key touch pad - or - via   dedicated software supplied    › P ossible to build in an access code  |   
Operating system  |    Windows for set-up and saving application data  |    Windows for set-up and saving application data  |    Windows for set-up and saving application data  |   
6 langues  |    French • English • German • Portuguese • Spanish • Italian  |    French • English • German • Portuguese • Spanish • Italian  |    French • English • German • Portuguese • Spanish • Italian  |   
Serial link  |    RS232 or RS485 to JBUS/MODBUS protocol • 9600 Bauds  |    RS232 or RS485 to JBUS/MODBUS protocol • 9600 Bauds  |    RS232 to JBUS/MODBUS    protocol • 9600 Bauds  |   
Accessory (optional)  |    1 RS232 to USB converter link cable  |    1 RS232 to USB converter link cable  |    1 RS232 to USB converter link cable  |   
ELECTRICAL    CHARACTERISTICS  |    › 2 Static relays (100V - 100mA - 10VA max)    › 1 RS232/RS485 serial link to MODBUS/JBUS protocol    › Basic power supply • Low voltage: 9-36V dc or 7-25V ac    › Optional power supply 18-72V dc or 90-230 V ac    › 2 current outputs, 4-20mA (1000 Ω galvanically isolated    as passive output/150 Ω impedance as an active output)  |    › 2 Static relays (100V - 100mA - 10VA max)    › 1 RS232/RS485 serial link to MODBUS/JBUS protocol    › Basic power supply • Low voltage: 9-36V dc or 7-25V ac    › Optional power supply 18-72V dc or 90-230 V ac    › 2 current outputs, 4-20mA (1000 Ω galvanically isolated    as passive output/150 Ω impedance as an active output)  |    › 2 Static relays    (100V - 100mA - 10VA max)    › 1 RS 232 serial link to    MODBUS/JBUS protocol    › 12V NiMh sealed internal    battery    › 100-240V ac charger and    aux. power supply function    › 2 active current outputs,    4-20mA (150Ω impedance)  |   
Enclosure  |    › C ast aluminium & epoxy paint    › 1.5kg • 237 x 108 x 79mm  |    › C ast aluminium & epoxy paint    › 6.6kg • 244 x 130 x 232mm  |    › ABS •Supplied with a slip caseand storage bag    › 835g • 220 x 115 x 64mm  |   
Protection  |    IP67 (except rack 19’’)  |    IP67  |    |
Temperature range  |    For use from 0°C to 50°C  |    For use from 0°C to 50°C  |    For use from 0°C to 50°C  |